- Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances
- Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
- For use in single rod or dual rod/remote sense applications. Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended
- Functional equivalent of S86, S8600, S8610 and S90 modules
- For use with natural or LP gas
Intermittent Pilot Control, Universal, -40 to 165 Deg F Temp. Rise, Electrical Rating: 24V, 60 Hz, 5-7/16 inch Width, 3-15/16 inch Height, Includes Damper Connection With Automatic Vent Damper Plug, Including Spark Cable Adapters, Standards: Canadian Standards Association Approved, For use in single rod or dual rod/remote sense applications, For Use With: Natural or LP gas, 1A Pilot, 2A Main @ 165 F, 1A Pilot, 1A Main @ 175 F Maximum Valve Load @ 24 VAC, For Use With: Residential, Commercial Heating Equipment With Single Rod Or Dual Rod Remote Sense Applications, Up to 30 sec Prepurge Time
-
Type: Universal
-
Temperature Rise: -40 to 165 Deg F
-
Electrical Rating: 24V, 60 Hz
-
Width: 5-7/16 inch
-
Height: 3-15/16 inch
-
For Use With: Natural or LP Gas, Residential, Commercial Heating Equipment With Single Rod Or Dual Rod Remote Sense
-
Max. Valve Load at 24VAC: 1A Pilot, 2A Main at 165 F, 1A Pilot, 1A Main at 175 F
-
Prepurge Time: Up to 30 sec
-
Includes: Damper Connection With Automatic Vent Damper Plug, Including Spark Cable Adapters
-
Standards: Canadian Standards Association Approved
-
Applications: For use in Single Rod or Dual Rod/Remote Sense Applications