- Universal tank design maximizes installation adaptability by offering models with top, front side and rear side inlet/outlet water connections
- Universal space saver design short heights and small jacket diameters result in greater installation flexibility
- System Sentinel™ LED diagnostic system our exclusive diagnostic system, with glowing LED lights, verifies system operation sequence by sequence
- Spark to pilot ignition system standard on all models, provides reliable and energy saving ignition sequencing by igniting the pilot only when the thermostat calls for heat
- Low profile automatic flue damper low profile design minimizes overall product height, new heavy duty vent hood supports are designed to withstand rigors of installation
Commercial Water Heater, Natural Gas, 6 inch Draft Hood Size, 120VAC Voltage Rating, Height/Cold Side Connection: 6 inch, Height/Gas Connection: 57-1/2 inch, Height/Side Hot Connection: 23-1/4 inch, Height/Top of Heater: 73-1/16 inch, Height/Top of Vent Connection: Intake: 3/4 inch, Exhaust: 23 inch, Height to T & P Opening: 57-1/2 inch, Direct Spark-To-Pilot Ignition Ignition, Input: 199000 BtuH, 30-1/4 inch Jacket Dia, 150psi Max. Pressure, Recovery @ 100 F Rise (GPH): 194 gph, Recovery @ 110 F Rise (GPH): 176 gph, Recovery @ 120 F Rise (GPH): 162 gph, Recovery @ 130 F Rise (GPH): 149 gph, Recovery @ 140 F Rise (GPH): 138 gph, Recovery @ 50 F Rise (GPH): 388 gph, Recovery @ 70 F Rise (GPH): 277 gph, Recovery @ 90 F Rise (GPH): 215 gph, Tank Capacity: 100 gal, Temperature Range: 180 deg F, Dimensions: 73-1/16 inch H x 30-1/4 inch W, Stainless Steel, Standards: CSA certified, ASME, UL Certified
-
Type: Natural Gas
-
Draft Hood Size: 6 inch
-
Voltage Rating: 120VAC
-
Height/Cold Side Connection: 6 inch
-
Height/Gas Connection: 57-1/2 inch
-
Tank Capacity: 100 gal
-
Height/Side Hot Connection: 23-1/4 inch
-
Height/Top of Heater: 73-1/16 inch
-
Height/Top of Vent Connection: 3/4 inch Intake, 23 inch Exhaust
-
Height to T & P Opening: 57-1/2 inch
-
Ignition Type: Direct Spark-to-Pilot Ignition
-
Input (BTU): 199000 BTUH
-
Jacket Diameter: 30-1/4 inch
-
Maximum Pressure Rating: 150 psi
-
Recovery at 100 F Rise (GPH): 194 gph
-
Recovery at 110 F Rise (GPH): 176 gph
-
Recovery at 120 F Rise (GPH): 162 gph
-
Recovery at 130 F Rise (GPH): 149 gph
-
Recovery at 140 F Rise (GPH): 138 gph
-
Recovery at 50 F Rise (GPH): 388 gph
-
Recovery at 70 F Rise (GPH): 277 gph
-
Recovery at 90 F Rise (GPH): 215 gph
-
Temperature Range: 180 Deg F
-
Material: Stainless Steel
-
Standards: CSA Certified, ASME, UL Listed